Back to Marlin 7"

Marlin 7"

Installation guide and fault reference

Installation

Faults & diagnostics

1 blinkSelf-test errorCritical

Signal: 1 blink + 1s pause

The board's power-on self-test failed

Cause: Internal hardware fault at startup

Remedy: Power-cycle the display; if it persists, return/replace the board

2 blinksCAN bus reception timeoutCritical

Signal: 2 blinks + 1s pause

No messages received on the CAN bus for more than 5 s

Cause: CAN cable disconnected/damaged; motherboard off or not transmitting; termination misconfigured

Remedy: Check CAN-L / CAN-H wiring on J2–J3; verify the motherboard is powered and running; set J7-R120 termination ON if the display is a bus end

3 blinksCAN bus transmission errorCritical

Signal: 3 blinks + 1s pause

Problem transmitting on the CAN bus

Cause: Bus short or overload; wiring/termination issue; faulty node on the bus

Remedy: Inspect CAN wiring and termination; check other devices on the bus

4 blinksEEPROM read errorWarning

Signal: 4 blinks + 1s pause

Failed to read parameters from EEPROM

Cause: Corrupted stored parameters

Remedy: Reload parameters via Atlantis EVO / microSD; if persistent, return the board

5 blinksEEPROM write errorWarning

Signal: 5 blinks + 1s pause

Failed to write parameters to EEPROM

Cause: EEPROM worn or faulty

Remedy: Retry programming; if persistent, return the board

Downloads