Back to Villa

Villa

Installation guide and fault reference

Connections & installation

Supply the Villa with 12–24 VDC and connect the signal line. It has 2 CANbus connectors (pass-through in/out): pin 1 +12/24 V, pin 2 CAN-H, pin 3 GND, pin 4 CAN-L. Input C selects the parallel-coding common (positive or negative); a switch inserts the CAN line impedance.

  • Keep signal wiring away from power cables
  • At power-up the display shows the firmware version, then lights all segments/symbols with a short buzzer tone for a visual check

Programming & parameters

The display is programmed with the ADV and OK buttons on the board:

  • P1 – operating modes
  • P2 – auto power-off
  • P3 – volume
  • P4 – 1-wire-per-floor (1ppp) signalling
  • P5 – floor offset
  • P6 – brightness
  • P7 – enable call collection
  • P8 – planned floor
  • P9 – other signalling

Diagnostics (RDY / ERR LEDs)

Two LEDs, RDY and ERR, assist diagnostics and programming.

RDY – short blink once per second: board operating normally; long blink once per second: board in programming or demo mode (not responding to CANbus).

ERR – off: no error. Blink codes (n blinks + 1 s pause):

  • 1 – no CANbus activity from BR100 for over 5 s (DISPLAY section)
  • 2 – no CANbus activity from BR100 for over 5 s (CHM2S section)
  • 3 – missing ACK message from BR100 after a send
  • 4 – inconsistent inputs (e.g. more than one active input in 1-pole-per-floor mode)
  • 5 – error sending a message on the CANbus
  • 6 – error reading the parameters in EEPROM