Back to Electronics
control boards
Limax
Absolute shaft positioning system reading a magnetic tape with an ELGO sensor to manage speeds and deceleration.
Absolute positioningCANopenELGO

- 7
- Max nominal current
Overview
The Limax system manages the pulses from a car sensor reading a magnetic tape in the shaft, so that after shaft acquisition it determines the target speeds and the deceleration points where the board starts low speed.
- ELGO Limax sensor connected in CANopen to the BR400 on port CAN4 (with the supplied CANbus terminator)
- Drives up to 7 binary multi-step inverter speeds, each with its own deceleration distance (params N5 D2–D7)
- On its own it needs a low-speed approach; paired with suitable inverters it enables direct-to-floor arrival
- With safety devices it allows door pre-opening at the floor
Specifications
| Usage | Absolute shaft positioning |
|---|---|
| Serial communication | CANopen (ELGO sensor → BR400 CAN4) |
| Outputs | RIF VEL0/1/2 speed references + PAT (or TB/TG/PAT) |
| Programming | BR400 params N15 (outputs), N5 (deceleration D2–D7) |
Compatibility
Movilift serial (CAN)VVVF drive